6WKU
Twelve Chloride Ions Drive Assembly of Human alpha345 Collagen IV NC1 domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-G |
Synchrotron site | APS |
Beamline | 21-ID-G |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2018-04-14 |
Detector | RAYONIX MX300HE |
Wavelength(s) | 0.97857 |
Spacegroup name | P 41 21 2 |
Unit cell lengths | 128.420, 128.420, 104.710 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 45.400 - 1.760 |
R-factor | 0.1395 |
Rwork | 0.139 |
R-free | 0.16150 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6mpx |
RMSD bond length | 0.006 |
RMSD bond angle | 0.896 |
Data reduction software | iMOSFLM (7.2.0) |
Data scaling software | Aimless |
Phasing software | MOLREP (11.5.04) |
Refinement software | PHENIX (1.17.1_3660) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 68.600 | 1.790 |
High resolution limit [Å] | 1.760 | 1.760 |
Rmerge | 0.083 | 0.488 |
Rmeas | 0.089 | 0.521 |
Rpim | 0.031 | 0.182 |
Number of reflections | 86926 | 4534 |
<I/σ(I)> | 13.1 | 3.4 |
Completeness [%] | 100.0 | 100 |
Redundancy | 8.2 | 8.2 |
CC(1/2) | 0.998 | 0.937 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8.5 | 295 | PEG 200, sodium chloride, tris |