Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6V8G

GltPh mutant - Y204L A345V V366A

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.2.1
Synchrotron siteALS
Beamline8.2.1
Temperature [K]100
Detector technologyCCD
Collection date2018-12-29
DetectorADSC QUANTUM 315r
Wavelength(s)0.99997
Spacegroup nameP 31 2 1
Unit cell lengths109.416, 109.416, 305.227
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution47.380 - 3.380
R-factor0.2336
Rwork0.232
R-free0.25740
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2nwx
RMSD bond length0.002
RMSD bond angle0.453
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.16_3549)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]47.3803.496
High resolution limit [Å]3.3753.375
Rmerge0.115
Rmeas0.121
Rpim0.036
Number of reflections306122964
<I/σ(I)>10.87
Completeness [%]99.5
Redundancy10.5
CC(1/2)0.9930.787
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP277Potassium citrate, PEG 400