6V4A
An open conformation of a Pentameic ligand-gated ion channel with additional N-terminal domain
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 193 |
Detector technology | PIXEL |
Collection date | 2016-07-08 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.9786 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 141.064, 116.028, 169.630 |
Unit cell angles | 90.00, 109.17, 90.00 |
Refinement procedure
Resolution | 25.000 - 3.830 |
R-factor | 0.2574 |
Rwork | 0.256 |
R-free | 0.29140 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 6fli |
RMSD bond length | 0.015 |
RMSD bond angle | 1.983 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0158) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 48.610 | 3.930 |
High resolution limit [Å] | 3.830 | 3.830 |
Number of reflections | 49576 | 3486 |
<I/σ(I)> | 7.6 | |
Completeness [%] | 99.3 | |
Redundancy | 3.8 | |
CC(1/2) | 0.999 | 0.448 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 291 | 0.3 M NH4-Formate, 0.1 M Tris 7.5, 30% (v/v) PEG-MME 500 |