Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6UM8

HIV Integrase in complex with Compound-14

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 17-ID
Synchrotron siteAPS
Beamline17-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2010-10-27
DetectorDECTRIS PILATUS 6M
Wavelength(s)1.0
Spacegroup nameP 43 3 2
Unit cell lengths164.626, 164.626, 164.626
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution116.410 - 2.330
R-factor0.198
Rwork0.196
R-free0.22000
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)6ncj
RMSD bond length0.010
RMSD bond angle1.060
Refinement softwareBUSTER (2.11.7)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]164.510164.510
High resolution limit [Å]2.3308.970
Number of reflections3329618666
<I/σ(I)>42.279.3
Completeness [%]100.0100
Redundancy38.529.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2932.0 M ammonium sulfate and 100 mM citric acid pH 3.5

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon