Mcl-1 bound to compound 17

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 21-ID-D
Synchrotron siteAPS
Beamline21-ID-D
Temperature [K]100
Detector technologyCCD
Collection date2013-02-14
DetectorMARMOSAIC 300 mm CCD
Wavelength(s)0.96295
Spacegroup nameH 3 2
Unit cell lengths111.680, 111.680, 72.340
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution28.960 - 2.550
R-factor0.2024
Rwork0.201
R-free0.23900
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.040
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwareMOLREP
Refinement softwareBUSTER (2.10.0)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]50.00050.0002.590
High resolution limit [Å]2.5406.9202.550
Rmerge0.0690.0580.649
Number of reflections5833301284
<I/σ(I)>15.1
Completeness [%]99.695100
Redundancy20.917.621.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP6.529330% PEG 3350, 0.2 mM MgCl2 and 0.1 M ADA pH 6.5