6QTN

Tubulin-cyclostreptin complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06DA
Synchrotron siteSLS
BeamlineX06DA
Temperature [K]100
Detector technologyPIXEL
Collection date2017-09-27
DetectorDECTRIS PILATUS 2M-F
Wavelength(s)1.00000
Spacegroup nameP 21 21 21
Unit cell lengths104.585, 158.361, 179.946
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution49.655 - 1.900
R-factor0.188
Rwork0.187
R-free0.21330
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)5lxt
RMSD bond length0.004
RMSD bond angle0.652
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.13_2998: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.7001.950
High resolution limit [Å]1.9001.900
Rmerge0.1024.485
Rmeas0.1044.572
Rpim0.0250.843
Number of reflections23434617147
<I/σ(I)>22.70.9
Completeness [%]100.0100
Redundancy26.827
CC(1/2)1.0000.322
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION6.72936% glycerol, 3% PEG4000, 0.1 M Mes/0.1 M imidazole pH 6.7, 30 mM CaCl2, 30 mM MgCl2

219869

PDB entries from 2024-05-15

PDB statisticsPDBj update infoContact PDBjnumon