6PAG
Killer cell immunoglobulin-like receptor 2DL3 in complex with HLA-C*07:02
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | AUSTRALIAN SYNCHROTRON BEAMLINE MX2 |
Synchrotron site | Australian Synchrotron |
Beamline | MX2 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-10-15 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.954 |
Spacegroup name | P 64 |
Unit cell lengths | 111.855, 111.855, 87.994 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 32.567 - 2.501 |
R-factor | 0.2242 |
Rwork | 0.223 |
R-free | 0.25410 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1efx |
RMSD bond length | 0.046 |
RMSD bond angle | 1.691 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX (1.8.1_1168) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.600 |
High resolution limit [Å] | 2.500 | 2.500 |
Number of reflections | 21403 | 2136 |
<I/σ(I)> | 14.2 | |
Completeness [%] | 98.5 | 98.7 |
Redundancy | 3.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 8 | 293 | 0.2 M Ammonium acetate, 0.1 M Tris-HCl pH.8.0 and 25% PEG 3350. |