6OON
Human Argonaute4 bound to guide RNA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-E |
Synchrotron site | APS |
Beamline | 24-ID-E |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-08-21 |
Detector | ADSC QUANTUM 315 |
Wavelength(s) | 0.987 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 213.980, 68.011, 83.270 |
Unit cell angles | 90.00, 102.68, 90.00 |
Refinement procedure
Resolution | 49.082 - 1.900 |
R-factor | 0.173 |
Rwork | 0.171 |
R-free | 0.20240 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4ola |
RMSD bond length | 0.008 |
RMSD bond angle | 1.117 |
Data reduction software | MOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.082 | 1.950 |
High resolution limit [Å] | 1.900 | 1.900 |
Number of reflections | 91128 | 14243 |
<I/σ(I)> | 1.91 | |
Completeness [%] | 98.9 | |
Redundancy | 4.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6 | 298 | PEG5000, 0.1 M MES, pH=6, 1 M LiCl, 100 mM Trimethylamine Hydrochloride |