Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

6MVM

LasR LBD L130F:3OC14HSL complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU RUH3R
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2017-12-07
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.00
Spacegroup nameP 1 21 1
Unit cell lengths44.881, 70.774, 53.817
Unit cell angles90.00, 90.15, 90.00
Refinement procedure
Resolution29.568 - 1.895
R-factor0.2231
Rwork0.213
R-free0.26540
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2uv0
RMSD bond length0.007
RMSD bond angle1.021
Data reduction softwareHKL-3000
Data scaling softwareHKL-3000
Phasing softwarePHENIX
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]30.0001.980
High resolution limit [Å]1.8951.900
Number of reflections25887
<I/σ(I)>14.4
Completeness [%]96.6
Redundancy2.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP298200 mM magnesium nitrate, 20% PEG3350

219869

PDB entries from 2024-05-15