HRAS G12S in complex with GDP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAPS BEAMLINE 19-ID
Synchrotron siteAPS
Beamline19-ID
Temperature [K]100
Detector technologyPIXEL
Collection date2017-10-12
DetectorDECTRIS PILATUS3 S 6M
Wavelength(s)0.9795
Spacegroup nameC 1 2 1
Unit cell lengths122.808, 79.773, 134.062
Unit cell angles90.00, 101.94, 90.00
Refinement procedure
Resolution39.445 - 1.498
R-factor0.1591
Rwork0.157
R-free0.19520
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)5b2z
Data reduction softwareHKL-3000
Data scaling softwareSCALEPACK
Phasing softwareMOLREP
Refinement softwarePHENIX (dev_2932)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.530
High resolution limit [Å]1.4901.500
Rpim0.02595.500
Number of reflections1952009667
<I/σ(I)>39.76.39
Completeness [%]96.695.5
Redundancy6.7
CC(1/2)0.9900.987
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.52930.2 M Sodium acetate trihydrate, 0.1 M TRIS hydrochloride pH 8.5, 30% w/v Polyethylene glycol 4,000