6LTI
HSP90 in complex with NVP-AUY922
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | SSRF BEAMLINE BL17U1 |
| Synchrotron site | SSRF |
| Beamline | BL17U1 |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2018-06-18 |
| Detector | DECTRIS EIGER X 16M |
| Wavelength(s) | 0.979 |
| Spacegroup name | I 2 2 2 |
| Unit cell lengths | 66.184, 89.288, 99.557 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 44.644 - 1.588 |
| R-factor | 0.1772 |
| Rwork | 0.176 |
| R-free | 0.19510 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Starting model (for MR) | 3tuh |
| RMSD bond length | 0.007 |
| RMSD bond angle | 0.844 |
| Data reduction software | HKL-3000 |
| Data scaling software | HKL-3000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.11.1_2575) |
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 50.000 | 1.620 |
| High resolution limit [Å] | 1.588 | 1.590 |
| Number of reflections | 76782 | 3819 |
| <I/σ(I)> | 6.5 | |
| Completeness [%] | 99.0 | |
| Redundancy | 6.8 | |
| CC(1/2) | 0.995 | 0.780 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 277 | 0.1M Tris-HCl pH8.5 0.2M MgCl2 25% PEG4000 |