THE GLIC PENTAMERIC LIGAND-GATED ION CHANNEL 2.22 resolution

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSOLEIL BEAMLINE PROXIMA 1
Synchrotron siteSOLEIL
BeamlinePROXIMA 1
Temperature [K]191
Detector technologyPIXEL
Collection date2015-10-11
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.9771
Spacegroup nameC 1 2 1
Unit cell lengths182.416, 133.401, 160.474
Unit cell angles90.00, 102.48, 90.00
Refinement procedure
Resolution20.000 - 2.220
R-factor0.1965
Rwork0.195
R-free0.22009
RMSD bond length0.019
RMSD bond angle2.234
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0158)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]49.3902.260
High resolution limit [Å]2.2202.220
Number of reflections169456
<I/σ(I)>8.7
Completeness [%]91.9
Redundancy2.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1EVAPORATION29112-14.5% PEG4K; 15% GLycerol; 400 mM NaSCN; 3% DMSO; 100mM NaAcetate pH 4.

219869