6HK6

Human RIOK2 bound to inhibitor

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyPIXEL
Collection date2016-02-08
DetectorDECTRIS PILATUS 2M
Wavelength(s)0.9201
Spacegroup nameP 1 21 1
Unit cell lengths92.010, 92.860, 237.650
Unit cell angles90.00, 99.10, 90.00
Refinement procedure
Resolution78.340 - 2.350
R-factor0.21595
Rwork0.215
R-free0.23543
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4gyi
RMSD bond length0.008
RMSD bond angle1.415
Data reduction softwareMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0232)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]92.8602.390
High resolution limit [Å]2.3502.350
Rmerge0.1100.590
Number of reflections1643338004
<I/σ(I)>6.61.8
Completeness [%]99.798.3
Redundancy3.12.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP29320% PEG3350, 10% ethylene glycol, 0.1 M bis-tris-propane pH 6.5 and 0.2 M sodium/potassium tartrat