6GPG
Structure of the RIG-I Singleton-Merten syndrome variant C268F
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06SA |
Synchrotron site | SLS |
Beamline | X06SA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-09-22 |
Detector | DECTRIS EIGER X 16M |
Wavelength(s) | 1.0 |
Spacegroup name | P 65 2 2 |
Unit cell lengths | 175.620, 175.620, 109.530 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 46.468 - 2.894 |
R-factor | 0.2121 |
Rwork | 0.210 |
R-free | 0.25970 |
RMSD bond length | 0.009 |
RMSD bond angle | 1.238 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.13_2998: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.468 | 3.000 |
High resolution limit [Å] | 2.894 | 2.894 |
Rmerge | 0.076 | |
Number of reflections | 22649 | |
<I/σ(I)> | 19.72 | |
Completeness [%] | 99.7 | |
Redundancy | 13.09 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M MOPS pH 7.5, 17.5 % (w/v) PEG 3350, 0.25 M NaSCN, 3 % (v/v) 2,2,2 trifluoroethanol |