6F8H
antitoxin GraA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 1 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 1 |
Temperature [K] | 90 |
Detector technology | PIXEL |
Collection date | 2014-10-07 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.97857 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 62.740, 48.950, 66.930 |
Unit cell angles | 90.00, 92.62, 90.00 |
Refinement procedure
Resolution | 46.806 - 2.002 |
R-factor | 0.1918 |
Rwork | 0.190 |
R-free | 0.22580 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.010 |
RMSD bond angle | 1.124 |
Data reduction software | XDS |
Data scaling software | Aimless |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.810 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.040 | 0.340 |
Number of reflections | 27427 | 2703 |
<I/σ(I)> | 19.67 | 3.71 |
Completeness [%] | 99.3 | 98.11 |
Redundancy | 3.7 | 3.7 |
CC(1/2) | 0.970 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1 M KCl, 0.1 M HEPES pH 7.5, 15%(w/v) PEG 6000 |