6EIJ
DYRK1A in complex with HG-8-60-1
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ESRF BEAMLINE ID23-1 |
Synchrotron site | ESRF |
Beamline | ID23-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-09-19 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.984003 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 89.240, 88.040, 228.500 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.400 - 2.420 |
R-factor | 0.21485 |
Rwork | 0.213 |
R-free | 0.24192 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4nct |
RMSD bond length | 0.009 |
RMSD bond angle | 1.237 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | REFMAC (5.8.0155) |
Data quality characteristics
Overall | Inner shell | Outer shell | |
Low resolution limit [Å] | 50.000 | 50.000 | 2.600 |
High resolution limit [Å] | 2.450 | 7.280 | 2.450 |
Rmeas | 0.107 | 0.044 | 0.688 |
Number of reflections | 66317 | 2754 | 10167 |
<I/σ(I)> | 14.24 | 38.02 | 2.47 |
Completeness [%] | 99.2 | 99.2 | 95.7 |
Redundancy | 6.4 | ||
CC(1/2) | 0.997 | 0.998 | 0.837 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.1 M KSCN; 0.05M KCl; 10% PEG 3350, pH 6.8 |