6DL7
Human mitochondrial ClpP in complex with ONC201 (TIC10)
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2018-01-14 |
Detector | DECTRIS PILATUS3 S 6M |
Wavelength(s) | 0.97949 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 142.390, 153.440, 104.790 |
Unit cell angles | 90.00, 117.58, 90.00 |
Refinement procedure
Resolution | 49.330 - 2.000 |
R-factor | 0.2278 |
Rwork | 0.226 |
R-free | 0.26200 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.003 |
RMSD bond angle | 0.568 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.330 | 2.071 |
High resolution limit [Å] | 2.000 | 2.000 |
Number of reflections | 133979 | |
<I/σ(I)> | 5.64 | |
Completeness [%] | 100.0 | |
Redundancy | 4.7 | |
CC(1/2) | 0.504 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 5.2 | 277 | 5%(w/v) PEG 4,000, 100mM KCl, 100mM NaAc (pH5.2) |