6DG0
MEC-8 C-terminal RRM domain bound to AGCACA
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU FR-X |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-01-01 |
Detector | DECTRIS PILATUS 200K |
Wavelength(s) | 0.97 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 72.075, 68.714, 57.531 |
Unit cell angles | 90.00, 122.40, 90.00 |
Refinement procedure
Resolution | 28.082 - 2.457 |
R-factor | 0.2376 |
Rwork | 0.235 |
R-free | 0.28710 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 1urn |
RMSD bond length | 0.003 |
RMSD bond angle | 0.779 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHENIX |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 28.082 | 2.544 |
High resolution limit [Å] | 2.457 | 2.457 |
Rmerge | 0.054 | 0.212 |
Rmeas | 0.076 | |
Number of reflections | 8221 | 658 |
<I/σ(I)> | 9.64 | 2.56 |
Completeness [%] | 94.1 | 76.33 |
Redundancy | 1.8 | 1.4 |
CC(1/2) | 0.996 | 0.932 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 294 | 1mM MES ph6.5, PEG 8000 25% |