6BVJ
Ras:SOS:Ras in complex with a small molecule activator
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-F |
Synchrotron site | APS |
Beamline | 21-ID-F |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2017-07-13 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 0.98 |
Spacegroup name | I 4 2 2 |
Unit cell lengths | 184.329, 184.329, 179.083 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 36.109 - 1.747 |
R-factor | 0.1562 |
Rwork | 0.155 |
R-free | 0.16790 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4nyi |
RMSD bond length | 0.007 |
RMSD bond angle | 0.855 |
Data reduction software | HKL-2000 |
Data scaling software | HKL-2000 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.12rc1_2801: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 36.110 | 1.810 |
High resolution limit [Å] | 1.747 | 1.747 |
Rpim | 0.033 | 0.296 |
Number of reflections | 153914 | |
<I/σ(I)> | 18.4 | |
Completeness [%] | 99.9 | |
Redundancy | 11.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 4 | 292 | 0.1 M sodium acetate, 2.0 M sodium formate, pH 4.0 |