Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5XX2

A BPTI-[5,55] variant with C14GA38L mutations

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPHOTON FACTORY BEAMLINE AR-NW12A
Synchrotron sitePhoton Factory
BeamlineAR-NW12A
Temperature [K]101
Detector technologyCCD
Collection date2010-10-25
DetectorAGILENT EOS CCD
Wavelength(s)1.0
Spacegroup nameP 1 21 1
Unit cell lengths25.413, 40.690, 61.147
Unit cell angles90.00, 89.99, 90.00
Refinement procedure
Resolution61.150 - 1.120
R-factor0.13126
Rwork0.130
R-free0.14575
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2zvx
RMSD bond length0.038
RMSD bond angle2.988
Data reduction softwareDENZO
Data scaling softwareSCALA
Refinement softwareREFMAC (5.8.0049)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]61.1501.040
High resolution limit [Å]1.0001.000
Rmerge0.289
Number of reflections67481
<I/σ(I)>6.326.32
Completeness [%]99.599.9
Redundancy6.46.4
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.5293.1530% PEG4000; 0.2M Lithium Sulfate; 0.1M Tris-HCl, pH8.5

225158

PDB entries from 2024-09-18

PDB statisticsPDBj update infoContact PDBjnumon