5X8M
PD-L1 in complex with durvalumab
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | PAL/PLS BEAMLINE 7A (6B, 6C1) |
| Synchrotron site | PAL/PLS |
| Beamline | 7A (6B, 6C1) |
| Temperature [K] | 100 |
| Detector technology | CCD |
| Collection date | 2016-12-04 |
| Detector | ADSC QUANTUM 270 |
| Wavelength(s) | 1.00 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 39.950, 97.395, 153.564 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 46.419 - 2.661 |
| R-factor | 0.1829 |
| Rwork | 0.181 |
| R-free | 0.21900 |
| RMSD bond length | 0.008 |
| RMSD bond angle | 1.105 |
| Data reduction software | HKL-2000 |
| Data scaling software | HKL-2000 |
| Phasing software | PHASER |
| Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 50.000 |
| High resolution limit [Å] | 2.660 |
| Number of reflections | 17827 |
| <I/σ(I)> | 16.5 |
| Completeness [%] | 99.4 |
| Redundancy | 3.2 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, HANGING DROP | 293 | 0.2M Ammonium sulfate, 0.1M Bis-Tris pH 5.5, 25% w/v PEG 3350 |