5X8M

PD-L1 in complex with durvalumab

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsPAL/PLS BEAMLINE 7A (6B, 6C1)
Synchrotron sitePAL/PLS
Beamline7A (6B, 6C1)
Temperature [K]100
Detector technologyCCD
Collection date2016-12-04
DetectorADSC QUANTUM 270
Wavelength(s)1.00
Spacegroup nameP 21 21 21
Unit cell lengths39.950, 97.395, 153.564
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.419 - 2.661
R-factor0.1829
Rwork0.181
R-free0.21900
RMSD bond length0.008
RMSD bond angle1.105
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]50.000
High resolution limit [Å]2.660
Number of reflections17827
<I/σ(I)>16.5
Completeness [%]99.4
Redundancy3.2
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2930.2M Ammonium sulfate, 0.1M Bis-Tris pH 5.5, 25% w/v PEG 3350

224004

PDB entries from 2024-08-21