H-Ras mutant L120A bound to GMP-PNP at 277K

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 8.3.1
Synchrotron siteALS
Beamline8.3.1
Temperature [K]277
Detector technologyPIXEL
Collection date2017-03-24
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.88557
Spacegroup nameH 3 2
Unit cell lengths89.988, 89.988, 135.969
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution45.323 - 1.350
R-factor0.1455
Rwork0.145
R-free0.15360
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)3k8y
RMSD bond length0.009
RMSD bond angle1.052
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.11.1_2575: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]45.3201.370
High resolution limit [Å]1.3501.350
Rmerge0.0992.972
Rpim0.0230.678
Number of reflections466422277
<I/σ(I)>16.21.2
Completeness [%]100.0100
Redundancy19.720
CC(1/2)0.9990.565
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP629317% PEG8000, 200 mM calcium acetate, 100 mM MES/NaOH, pH 6.0