Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 24-ID-C |
Synchrotron site | APS |
Beamline | 24-ID-C |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-07-29 |
Detector | DECTRIS PILATUS 6M-F |
Wavelength(s) | 0.9791 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 210.750, 450.050, 626.640 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 16.600 - 3.900 |
Structure solution method | MOLECULAR REPLACEMENT |
Refinement software | PHENIX |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 16.600 |
High resolution limit [Å] | 3.700 |
Number of reflections | 592026 |
<I/σ(I)> | 5.5 |
Completeness [%] | 94.6 |
Redundancy | 4.8 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 5% PEG 20k, 5% PEG 550 MME, 100 mM TRIS-ACETATE, 200 mM KSCN, 10 mM MAGNESIUM CHLORIDE |