Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | APS BEAMLINE 24-ID-C |
| Synchrotron site | APS |
| Beamline | 24-ID-C |
| Temperature [K] | 100 |
| Detector technology | PIXEL |
| Collection date | 2015-07-29 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.9791 |
| Spacegroup name | P 21 21 21 |
| Unit cell lengths | 210.750, 450.050, 626.640 |
| Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
| Resolution | 16.600 - 3.900 |
| Structure solution method | MOLECULAR REPLACEMENT |
| Refinement software | PHENIX |
Data quality characteristics
| Overall | |
| Low resolution limit [Å] | 16.600 |
| High resolution limit [Å] | 3.700 |
| Number of reflections | 592026 |
| <I/σ(I)> | 5.5 |
| Completeness [%] | 94.6 |
| Redundancy | 4.8 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 7 | 293 | 5% PEG 20k, 5% PEG 550 MME, 100 mM TRIS-ACETATE, 200 mM KSCN, 10 mM MAGNESIUM CHLORIDE |






