Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5VLK

Short PCSK9 delta-P' complex with shrunken peptide bearing homo-Arginine

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSSRL BEAMLINE BL12-2
Synchrotron siteSSRL
BeamlineBL12-2
Temperature [K]110
Detector technologyPIXEL
Collection date2017-01-18
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97946
Spacegroup nameP 32 2 1
Unit cell lengths70.387, 70.387, 156.983
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution50.010 - 2.200
R-factor0.19702
Rwork0.195
R-free0.23703
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4nmx
RMSD bond length0.008
RMSD bond angle1.260
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0102.280
High resolution limit [Å]2.2002.200
Number of reflections23637
<I/σ(I)>16.12.5
Completeness [%]100.097.2
Redundancy9.99.3
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8292calcium acetate, PEG 6000

223166

PDB entries from 2024-07-31

PDB statisticsPDBj update infoContact PDBjnumon