Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-12-01 |
Detector | ADSC QUANTUM 4r |
Wavelength(s) | 1 |
Spacegroup name | C 2 2 21 |
Unit cell lengths | 126.902, 171.950, 135.766 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 27.259 - 1.900 |
R-factor | 0.1764 |
Rwork | 0.175 |
R-free | 0.20950 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 4ma9 |
RMSD bond length | 0.012 |
RMSD bond angle | 1.254 |
Data reduction software | iMOSFLM |
Data scaling software | SCALA |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 28.100 |
High resolution limit [Å] | 1.900 |
Number of reflections | 225895 |
<I/σ(I)> | 13.2 |
Completeness [%] | 100.0 |
Redundancy | 19.6 |
CC(1/2) | 0.200 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 300 | 1.4 MgSO4, 0.1 M MES pH 6.5. |