Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 14-BM-C |
Synchrotron site | APS |
Beamline | 14-BM-C |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2002-02-13 |
Detector | ADSC QUANTUM 4 |
Wavelength(s) | 0.9 |
Spacegroup name | P 21 3 |
Unit cell lengths | 188.792, 188.792, 188.792 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 84.430 - 2.000 |
R-factor | 0.1831 |
Rwork | 0.176 |
R-free | 0.20600 |
RMSD bond length | 0.004 |
RMSD bond angle | 0.868 |
Refinement software | PHENIX ((1.11.1_2575: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 100.000 | 2.070 |
High resolution limit [Å] | 2.000 | 2.000 |
Rmerge | 0.132 | 0.532 |
Number of reflections | 148902 | |
Completeness [%] | 99.0 | 98.8 |
Redundancy | 40 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 3.4~4.0 M sodium formate, 50 mM Tris, pH 7.5 |