5OPD
Structure of phosphorylated EF-Tu in complex with GTP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SOLEIL BEAMLINE PROXIMA 2 |
Synchrotron site | SOLEIL |
Beamline | PROXIMA 2 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2017-07-01 |
Detector | DECTRIS EIGER X 9M |
Wavelength(s) | 1.8369 |
Spacegroup name | P 1 |
Unit cell lengths | 59.840, 61.880, 65.480 |
Unit cell angles | 70.37, 75.83, 89.41 |
Refinement procedure
Resolution | 51.370 - 2.750 |
R-factor | 0.185 |
Rwork | 0.181 |
R-free | 0.25800 |
Structure solution method | SAD |
RMSD bond length | 0.009 |
RMSD bond angle | 1.240 |
Data reduction software | XDS |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER (2.10.3) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 51.370 |
High resolution limit [Å] | 2.750 |
Number of reflections | 20752 |
<I/σ(I)> | 9 |
Completeness [%] | 96.6 |
Redundancy | 6 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 6.5 | 293 | 20% PEG3550, 0.1 M Bis-Tris propane pH 6.5 and 0.2 M Sodium Iodide |