5OHV
K33-specific affimer bound to K33 diUb
Experimental procedure
| Experimental method | SINGLE WAVELENGTH |
| Source type | SYNCHROTRON |
| Source details | DIAMOND BEAMLINE I04 |
| Synchrotron site | Diamond |
| Beamline | I04 |
| Temperature [K] | 110 |
| Detector technology | PIXEL |
| Collection date | 2015-01-23 |
| Detector | DECTRIS PILATUS 6M-F |
| Wavelength(s) | 0.979490 |
| Spacegroup name | H 3 |
| Unit cell lengths | 120.288, 120.288, 69.973 |
| Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Data quality characteristics
| Overall | Outer shell | |
| Low resolution limit [Å] | 60.144 | 3.936 |
| High resolution limit [Å] | 2.800 | 3.800 |
| Rmerge | 0.237 | 0.794 |
| Number of reflections | 9294 | |
| <I/σ(I)> | 5 | 2 |
| Completeness [%] | 100.0 | 100 |
| Redundancy | 7 | 7.1 |
| CC(1/2) | 0.679 |
Crystallization Conditions
| crystal ID | method | pH | temperature | details |
| 1 | VAPOR DIFFUSION, SITTING DROP | 5.2 | 295 | 21% PEG 3350 200 mM Li2SO4 100 mM NaOAc pH 5.2 |