5O49
Human FGF in complex with a covalent inhibitor
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2016-07-22 |
Detector | DECTRIS PILATUS 6M |
Wavelength(s) | 0.97625 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 209.550, 57.590, 65.620 |
Unit cell angles | 90.00, 107.64, 90.00 |
Refinement procedure
Resolution | 49.920 - 1.910 |
R-factor | 0.2 |
R-free | 0.22000 |
Data reduction software | xia2 |
Data scaling software | Aimless |
Phasing software | PHASER |
Refinement software | BUSTER-TNT |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 49.920 | 1.960 |
High resolution limit [Å] | 1.910 | 1.910 |
Rmerge | 0.036 | 0.735 |
Number of reflections | 57050 | 4147 |
<I/σ(I)> | 13.9 | 1.5 |
Completeness [%] | 98.2 | 97.8 |
Redundancy | 3.2 | 2.8 |
CC(1/2) | 0.998 | 0.548 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 277 | 18-20% (w/v) PEG8000, 200mM ammonium sulphate, 100mM PCTP pH 6.75 and 20% (v/v) ethylene glycol |