Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5NOI

human Robo2 extracellular domains 4-5

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID30B
Synchrotron siteESRF
BeamlineID30B
Temperature [K]100
Detector technologyPIXEL
Collection date2015-06-29
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)1.008818
Spacegroup nameI 41 2 2
Unit cell lengths99.749, 99.749, 123.465
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution38.800 - 2.400
R-factor0.2401
Rwork0.237
R-free0.26690
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4c4k 2edj
RMSD bond length0.023
RMSD bond angle1.915
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.10.1_2155: ???))
Data quality characteristics
 Overall
Low resolution limit [Å]38.800
High resolution limit [Å]2.400
Number of reflections12530
<I/σ(I)>21.6
Completeness [%]100.0
Redundancy12.5
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2771.1M NaCl, 11-13% PEG 6000

218500

PDB entries from 2024-04-17

PDB statisticsPDBj update infoContact PDBjnumon