5NKM

SMG8-SMG9 complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X10SA
Synchrotron siteSLS
BeamlineX10SA
Temperature [K]100
Detector technologyPIXEL
Collection date2015-05-27
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.979
Spacegroup nameP 32 2 1
Unit cell lengths111.085, 111.085, 374.474
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution62.412 - 2.493
R-factor0.2264
Rwork0.225
R-free0.26020
Structure solution methodSAD
RMSD bond length0.003
RMSD bond angle0.568
Data reduction softwareXDS
Data scaling softwareXDS
Phasing softwareSHELXD
Refinement softwarePHENIX (1.11.1_2575)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]52.3602.583
High resolution limit [Å]2.4932.493
Rmerge0.1372.587
Number of reflections188934
<I/σ(I)>27.25
Completeness [%]98.0
Redundancy39
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.528510% PEG3350, 0.1M Tris pH 8.5