5NFZ

TUBULIN-MTC complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsSLS BEAMLINE X06SA
Synchrotron siteSLS
BeamlineX06SA
Temperature [K]100
Detector technologyPIXEL
Collection date2013-05-02
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.97976
Spacegroup nameP 21 21 21
Unit cell lengths105.163, 158.787, 180.376
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution59.782 - 2.100
R-factor0.1839
Rwork0.182
R-free0.21760
Structure solution methodFOURIER SYNTHESIS
Starting model (for MR)4i4t
RMSD bond length0.007
RMSD bond angle0.856
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHENIX
Refinement softwarePHENIX ((1.10.1_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]59.7822.150
High resolution limit [Å]2.1002.100
Rmerge0.1352.890
Rpim0.0420.879
Number of reflections17586212854
<I/σ(I)>16.20.92
Completeness [%]100.099.8
Redundancy13.510.6
CC(1/2)0.9990.452
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION6.72935% PEG 4K, 12-14% glycerol, 30 mM MgCl2, 30 mM CaCl2, 100 mM MES/Imidazole, pH 6.7