Kinetic and Structural Changes in HsmtPheRS, Induced by Pathogenic Mutations in Human FARS2

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]295
Detector technologyPIXEL
Collection date2016-02-19
DetectorDECTRIS PILATUS 6M-F
Wavelength(s)0.97
Spacegroup nameP 21 21 21
Unit cell lengths54.539, 90.133, 97.467
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution46.662 - 1.890
R-factor0.2039
Rwork0.202
R-free0.24380
RMSD bond length0.007
RMSD bond angle0.971
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 Overall
Low resolution limit [Å]46.662
High resolution limit [Å]1.890
Number of reflections38365
<I/σ(I)>22.14
Completeness [%]98.0
Redundancy4.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2922 mM DTT, 100 mM bis-Tris propane pH 7 and 1.8 M sodium acetate pH 7

223790