5M5F
Thermolysin in complex with inhibitor and krypton
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ELETTRA BEAMLINE 5.2R |
Synchrotron site | ELETTRA |
Beamline | 5.2R |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-10-05 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 0.859400 |
Spacegroup name | P 61 2 2 |
Unit cell lengths | 92.428, 92.428, 130.192 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 43.552 - 1.330 |
R-factor | 0.1127 |
Rwork | 0.111 |
R-free | 0.13870 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 8tln |
RMSD bond length | 0.011 |
RMSD bond angle | 1.169 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.410 |
High resolution limit [Å] | 1.330 | 1.330 |
Rmerge | 0.499 | |
Number of reflections | 75575 | |
<I/σ(I)> | 25.98 | 6.26 |
Completeness [%] | 100.0 | 99.7 |
Redundancy | 20.7 | 19.5 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 7.5 | 291.15 | 50 MM TRIS/HCL, 1.9 M CSCL, 50% DMSO |