5M13
Synthetic nanobody in complex with MBP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SLS BEAMLINE X06DA |
Synchrotron site | SLS |
Beamline | X06DA |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-02-16 |
Detector | DECTRIS PILATUS 2M |
Wavelength(s) | 1.00004 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 58.298, 82.789, 102.583 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.666 - 1.372 |
R-factor | 0.1691 |
Rwork | 0.168 |
R-free | 0.18600 |
RMSD bond length | 0.005 |
RMSD bond angle | 0.750 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 50.000 |
High resolution limit [Å] | 1.372 |
Number of reflections | 196280 |
<I/σ(I)> | 10.04 |
Completeness [%] | 97.8 |
Redundancy | 2.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293.15 | 100 mM Tris pH 8.5, 25 % PEG3350 |