5LXI
GABARAP-L1 ATG4B LIR Complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | DIAMOND BEAMLINE I03 |
Synchrotron site | Diamond |
Beamline | I03 |
Temperature [K] | 100 |
Detector technology | PIXEL |
Collection date | 2015-10-08 |
Detector | DECTRIS PILATUS3 6M |
Wavelength(s) | 0.976 |
Spacegroup name | C 1 2 1 |
Unit cell lengths | 124.888, 72.377, 30.620 |
Unit cell angles | 90.00, 99.21, 90.00 |
Refinement procedure
Resolution | 31.207 - 1.440 |
R-factor | 0.1987 |
Rwork | 0.197 |
R-free | 0.22990 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2r2q |
RMSD bond length | 0.014 |
RMSD bond angle | 1.159 |
Data reduction software | xia2 |
Data scaling software | xia2 |
Phasing software | PHASER |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 35.000 | 1.470 |
High resolution limit [Å] | 1.440 | 1.440 |
Rmerge | 0.350 | |
Number of reflections | 46217 | |
<I/σ(I)> | 10.1 | 1.3 |
Completeness [%] | 96.0 | 93.7 |
Redundancy | 3.1 | 3 |
CC(1/2) | 0.998 | 0.740 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, SITTING DROP | 293 | 0.1 M MgCl2, 24.6 % PEG 400, 29.5 % PEG 8000, 0.1M TRIS 8.5 |