5LXI

GABARAP-L1 ATG4B LIR Complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I03
Synchrotron siteDiamond
BeamlineI03
Temperature [K]100
Detector technologyPIXEL
Collection date2015-10-08
DetectorDECTRIS PILATUS3 6M
Wavelength(s)0.976
Spacegroup nameC 1 2 1
Unit cell lengths124.888, 72.377, 30.620
Unit cell angles90.00, 99.21, 90.00
Refinement procedure
Resolution31.207 - 1.440
R-factor0.1987
Rwork0.197
R-free0.22990
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2r2q
RMSD bond length0.014
RMSD bond angle1.159
Data reduction softwarexia2
Data scaling softwarexia2
Phasing softwarePHASER
Refinement softwarePHENIX ((1.10.1_2155: ???))
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]35.0001.470
High resolution limit [Å]1.4401.440
Rmerge0.350
Number of reflections46217
<I/σ(I)>10.11.3
Completeness [%]96.093.7
Redundancy3.13
CC(1/2)0.9980.740
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP2930.1 M MgCl2, 24.6 % PEG 400, 29.5 % PEG 8000, 0.1M TRIS 8.5