5LTZ

GmhA_mutant Q175E

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I02
Synchrotron siteDiamond
BeamlineI02
Temperature [K]100
Detector technologyCCD
Collection date2016-02-16
DetectorADSC QUANTUM 4
Wavelength(s)0.97950
Spacegroup nameP 21 21 21
Unit cell lengths72.550, 84.473, 126.682
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution26.250 - 1.670
R-factor0.2095
Rwork0.207
R-free0.24470
RMSD bond length0.007
RMSD bond angle1.059
Data reduction softwareXDS
Data scaling softwareSCALA
Phasing softwareMOLREP
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 Overall
Low resolution limit [Å]50.870
High resolution limit [Å]1.670
Number of reflections90441
<I/σ(I)>11.8
Completeness [%]98.4
Redundancy6.8
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1BATCH MODE277.15B. pseudomallei GmhA at 10 mg per mL was mixed with an equal volume of crystallization solution: 0.1 M Na Acetate, pH 4.6, 8% PEG 4000

222926

PDB entries from 2024-07-24