5KY4
mouse POFUT1 in complex with mouse Notch1 EGF26 and GDP
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | CLSI BEAMLINE 08ID-1 |
Synchrotron site | CLSI |
Beamline | 08ID-1 |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2012-04-01 |
Detector | RAYONIX MX-300 |
Wavelength(s) | 0.97949 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 51.920, 66.372, 110.910 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 47.023 - 1.472 |
R-factor | 0.154 |
Rwork | 0.153 |
R-free | 0.16750 |
RMSD bond length | 0.007 |
RMSD bond angle | 1.014 |
Data reduction software | XDS |
Data scaling software | XSCALE |
Phasing software | PHASER |
Refinement software | PHENIX (1.10.1_2155) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 1.530 |
High resolution limit [Å] | 1.470 | 1.470 |
Rmerge | 0.134 | 1.218 |
Number of reflections | 65598 | |
<I/σ(I)> | 7.6 | 1.3 |
Completeness [%] | 100.0 | 99 |
Redundancy | 7.2 | 6.8 |
CC(1/2) | 0.991 | 0.537 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |