Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5KY4

mouse POFUT1 in complex with mouse Notch1 EGF26 and GDP

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsCLSI BEAMLINE 08ID-1
Synchrotron siteCLSI
Beamline08ID-1
Temperature [K]100
Detector technologyCCD
Collection date2012-04-01
DetectorRAYONIX MX-300
Wavelength(s)0.97949
Spacegroup nameP 21 21 21
Unit cell lengths51.920, 66.372, 110.910
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution47.023 - 1.472
R-factor0.154
Rwork0.153
R-free0.16750
RMSD bond length0.007
RMSD bond angle1.014
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.10.1_2155)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.530
High resolution limit [Å]1.4701.470
Rmerge0.1341.218
Number of reflections65598
<I/σ(I)>7.61.3
Completeness [%]100.099
Redundancy7.26.8
CC(1/2)0.9910.537
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP8.529520% PEG2000 MME, 50 mM Tris pH 8.5

225946

PDB entries from 2024-10-09