5KQZ
Protease E35D-CaP2
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | ROTATING ANODE |
Source details | RIGAKU RUH3R |
Temperature [K] | 100 |
Detector technology | IMAGE PLATE |
Collection date | 2015-02-11 |
Detector | RIGAKU |
Wavelength(s) | 1.5418 |
Spacegroup name | P 2 21 21 |
Unit cell lengths | 46.060, 58.430, 86.300 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 22.200 - 1.700 |
Rwork | 0.183 |
R-free | 0.21500 |
Data reduction software | iMOSFLM (7.1.1) |
Data scaling software | Aimless |
Phasing software | PHASER (2.1) |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 22.200 |
High resolution limit [Å] | 1.700 |
Number of reflections | 23936 |
<I/σ(I)> | 16.7 |
Completeness [%] | 99.0 |
Redundancy | 6.87 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 300 | sodium chloride |