5JEK
Phosphorylated MAVS in complex with IRF-3
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | ALS BEAMLINE 5.0.1 |
Synchrotron site | ALS |
Beamline | 5.0.1 |
Temperature [K] | 120 |
Detector technology | CCD |
Collection date | 2015-05-12 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 1.0 |
Spacegroup name | P 1 21 1 |
Unit cell lengths | 38.800, 104.910, 66.270 |
Unit cell angles | 90.00, 106.13, 90.00 |
Refinement procedure
Resolution | 63.661 - 2.400 |
R-factor | 0.1945 |
Rwork | 0.189 |
R-free | 0.25060 |
RMSD bond length | 0.002 |
RMSD bond angle | 0.605 |
Data reduction software | DENZO |
Data scaling software | SCALEPACK |
Phasing software | PHASER |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 64.000 |
High resolution limit [Å] | 2.400 |
Number of reflections | 19995 |
<I/σ(I)> | 14.3 |
Completeness [%] | 100.0 |
Redundancy | 7.2 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 277 | 0.1 M Bis-Tris pH 5.5, 80 mM MgCl2, 20% PEG 3350 |