Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 19-ID |
Synchrotron site | APS |
Beamline | 19-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2014-11-05 |
Detector | ADSC QUANTUM 315r |
Wavelength(s) | 0.97918 |
Spacegroup name | P 43 21 2 |
Unit cell lengths | 128.320, 128.320, 277.507 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 48.810 - 2.910 |
R-factor | 0.24635 |
Rwork | 0.243 |
R-free | 0.30775 |
Structure solution method | MOLECULAR REPLACEMENT |
Starting model (for MR) | 2z64 |
RMSD bond length | 0.011 |
RMSD bond angle | 1.680 |
Data reduction software | HKL-3000 |
Data scaling software | HKL-3000 |
Phasing software | PHASER |
Refinement software | REFMAC (5.7.0032) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.950 |
High resolution limit [Å] | 2.900 | 2.900 |
Rmerge | 0.083 | |
Number of reflections | 51785 | |
<I/σ(I)> | 8.7 | |
Completeness [%] | 99.6 | |
Redundancy | 7.9 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 7.5 | 293 | 0.1 M Bicine, pH 7.5, 12% PEG10000 |