5HVW
Monomeric IgG4 Fc
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 21-ID-F |
Synchrotron site | APS |
Beamline | 21-ID-F |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-08-15 |
Detector | MARMOSAIC 225 mm CCD |
Wavelength(s) | 1.000 |
Spacegroup name | H 3 2 |
Unit cell lengths | 121.379, 121.379, 99.729 |
Unit cell angles | 90.00, 90.00, 120.00 |
Refinement procedure
Resolution | 24.000 - 1.950 |
R-factor | 0.21165 |
Rwork | 0.209 |
R-free | 0.25824 |
RMSD bond length | 0.015 |
RMSD bond angle | 1.845 |
Data reduction software | HKL-2000 |
Data scaling software | SCALEPACK |
Phasing software | MOLREP |
Refinement software | REFMAC (5.8.0131) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 46.500 | 2.020 |
High resolution limit [Å] | 1.950 | 1.950 |
Rmerge | 0.064 | 0.718 |
Number of reflections | 19638 | |
<I/σ(I)> | 33.1 | 2.2 |
Completeness [%] | 99.9 | 100 |
Redundancy | 11.1 | 11.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION | 293 | 9 mM ZnCl2, 90 mM Hepes, pH 7.0, 18% PEG 6000 (w/v) |