5GOF
Truncated mitofusin-1, GTP-bound
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | SSRF BEAMLINE BL17U |
Synchrotron site | SSRF |
Beamline | BL17U |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2015-12-12 |
Detector | RAYONIX MX-225 |
Wavelength(s) | 0.97915 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 70.579, 72.461, 95.344 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 29.105 - 1.604 |
R-factor | 0.1811 |
Rwork | 0.179 |
R-free | 0.21450 |
Structure solution method | MOLECULAR REPLACEMENT |
RMSD bond length | 0.005 |
RMSD bond angle | 0.812 |
Data reduction software | XDS |
Data scaling software | XDS |
Phasing software | MOLREP |
Refinement software | PHENIX ((1.10.1_2155: ???)) |
Data quality characteristics
Overall | |
Low resolution limit [Å] | 44.660 |
High resolution limit [Å] | 1.600 |
Number of reflections | 426491 |
<I/σ(I)> | 25.54 |
Completeness [%] | 89.4 |
Redundancy | 7.1 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 293 | 1mM ZnCl2, 100mM Tris-HCl (pH 8.0~9.0), 15~16% PEG 3350, 10~15% glycerol |