5FLP

Native state mass spectrometry, surface plasmon resonance and X-ray crystallography correlate strongly as a fragment screening combination

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsAUSTRALIAN SYNCHROTRON BEAMLINE MX1
Synchrotron siteAustralian Synchrotron
BeamlineMX1
Temperature [K]100
Detector technologyCCD
Collection date2015-04-08
DetectorADSC CCD
Spacegroup nameP 1 21 1
Unit cell lengths42.387, 41.472, 72.287
Unit cell angles90.00, 104.43, 90.00
Refinement procedure
Resolution70.010 - 1.710
R-factor0.14787
Rwork0.146
R-free0.19245
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4cq0
RMSD bond length0.020
RMSD bond angle1.995
Data reduction softwareXDS
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwareREFMAC (5.8.0131)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]41.5001.740
High resolution limit [Å]1.7101.710
Rmerge0.1000.730
Number of reflections26161
<I/σ(I)>15.42.5
Completeness [%]98.090.9
Redundancy7.57
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP8.515 MG/ML PROTEIN WITH 2.7 M AMMONIUM SULFATE, 100 MM TRIS PH 8.5 AT 8 C IN SITTING DROPS.