5EZC

A de novo designed heptameric coiled coil CC-Hept-I18C-L22H-I25E

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsDIAMOND BEAMLINE I04
Synchrotron siteDiamond
BeamlineI04
Temperature [K]90
Detector technologyPIXEL
Collection date2014-05-14
DetectorPSI PILATUS 6M
Wavelength(s)0.979
Spacegroup nameI 1 2 1
Unit cell lengths62.252, 60.880, 69.380
Unit cell angles90.00, 110.89, 90.00
Refinement procedure
Resolution44.376 - 1.800
R-factor0.1888
Rwork0.187
R-free0.21960
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4pna
RMSD bond length0.007
RMSD bond angle0.819
Data reduction softwareiMOSFLM
Data scaling softwareAimless
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1496)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]53.9001.840
High resolution limit [Å]1.8001.800
Rmerge0.0760.475
Number of reflections22242
<I/σ(I)>7.72.3
Completeness [%]98.997.8
Redundancy33.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP72920.2 M MgCl2, 0.1 M Tris at pH 7.0 with 10% w/v PEG

237735