Mutagenicity of 7-Benzyl guanine lesion and Replication by Human DNA Polymerase beta

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeROTATING ANODE
Source detailsRIGAKU MICROMAX-007 HF
Temperature [K]100
Detector technologyIMAGE PLATE
Collection date2014-05-03
DetectorRIGAKU RAXIS IV++
Wavelength(s)1.5418
Spacegroup nameP 1 21 1
Unit cell lengths50.754, 80.015, 55.589
Unit cell angles90.00, 107.76, 90.00
Refinement procedure
Resolution19.818 - 2.088
R-factor0.1863
Rwork0.183
R-free0.23820
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)2fms
RMSD bond length0.009
RMSD bond angle1.291
Data reduction softwareDENZO
Data scaling softwareHKL-2000
Phasing softwareREFMAC
Refinement softwarePHENIX ((1.10.1_2155: ???))
Data quality characteristics
 Overall
Low resolution limit [Å]20.000
High resolution limit [Å]2.088
Rmerge0.098
Number of reflections25149
<I/σ(I)>18.1
Completeness [%]100.0
Redundancy4.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.529814% to 23% PEG3400, and 350 mM sodium acetate in 50 mM imidazole (pH 7.5)