5E6D
Glucocorticoid receptor DNA binding domain - ICAM1 NF-kB response element complex
Experimental procedure
Experimental method | SINGLE WAVELENGTH |
Source type | SYNCHROTRON |
Source details | APS BEAMLINE 22-ID |
Synchrotron site | APS |
Beamline | 22-ID |
Temperature [K] | 100 |
Detector technology | CCD |
Collection date | 2013-02-18 |
Detector | MARMOSAIC 300 mm CCD |
Wavelength(s) | 1.00 |
Spacegroup name | P 21 21 21 |
Unit cell lengths | 39.059, 97.145, 104.018 |
Unit cell angles | 90.00, 90.00, 90.00 |
Refinement procedure
Resolution | 32.655 - 2.400 |
R-factor | 0.2584 |
Rwork | 0.257 |
R-free | 0.28350 |
RMSD bond length | 0.012 |
RMSD bond angle | 1.288 |
Data scaling software | HKL-2000 |
Phasing software | PHENIX |
Refinement software | PHENIX (1.9_1692) |
Data quality characteristics
Overall | Outer shell | |
Low resolution limit [Å] | 50.000 | 2.250 |
High resolution limit [Å] | 2.170 | 2.170 |
Number of reflections | 21692 | |
<I/σ(I)> | 16.2 | 1.8 |
Completeness [%] | 96.6 | 91.6 |
Redundancy | 5.1 | 4.3 |
Crystallization Conditions
crystal ID | method | pH | temperature | details |
1 | VAPOR DIFFUSION, HANGING DROP | 298 | 0.1 M HEPES pH 7.7, 3% ethylene glycol, 10% PEG 8000 |