Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5DPE

Thermolysin in complex with inhibitor.

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsBESSY BEAMLINE 14.2
Synchrotron siteBESSY
Beamline14.2
Temperature [K]100
Detector technologyCCD
Collection date2012-07-12
DetectorMARMOSAIC 225 mm CCD
Wavelength(s)0.91841
Spacegroup nameP 61 2 2
Unit cell lengths92.690, 92.690, 130.261
Unit cell angles90.00, 90.00, 120.00
Refinement procedure
Resolution34.169 - 1.340
R-factor0.1286
Rwork0.127
R-free0.15580
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)8tln
RMSD bond length0.007
RMSD bond angle1.183
Data reduction softwareHKL-2000
Data scaling softwareHKL-2000
Phasing softwarePHASER
Refinement softwarePHENIX (1.8.4_1492)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]50.0001.360
High resolution limit [Å]1.3401.340
Number of reflections72715
<I/σ(I)>35.8134.38
Completeness [%]97.697.1
Redundancy10.37.1
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, SITTING DROP7.5291.1550 MM TRIS/HCL, 1.9 M CSCL, 50% DMSO,

222415

PDB entries from 2024-07-10

PDB statisticsPDBj update infoContact PDBjnumon