Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5D3M

Folate ECF transporter: AMPPNP bound state

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsESRF BEAMLINE ID23-1
Synchrotron siteESRF
BeamlineID23-1
Temperature [K]100
Detector technologyPIXEL
Collection date2015-01-28
DetectorDECTRIS PILATUS 6M
Wavelength(s)0.972423
Spacegroup nameP 1
Unit cell lengths90.070, 97.260, 105.450
Unit cell angles84.67, 64.78, 62.59
Refinement procedure
Resolution43.862 - 3.303
R-factor0.2523
Rwork0.250
R-free0.28920
Structure solution methodMOLECULAR REPLACEMENT
Starting model (for MR)4hzu
RMSD bond length0.006
RMSD bond angle1.404
Data reduction softwareXDS
Data scaling softwareXSCALE
Phasing softwarePHASER
Refinement softwarePHENIX (1.9_1692)
Data quality characteristics
 OverallOuter shell
Low resolution limit [Å]44.0003.400
High resolution limit [Å]3.3003.300
Rmerge0.0260.867
Number of reflections40590
<I/σ(I)>120.5
Completeness [%]94.494.4
Redundancy1.81.7
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP7.527750mM TRIS, 17% PEG 350 MME, 2% NG, 10mM spermidine, 10mM MgCl2, 10mM AMP-PNP

226707

PDB entries from 2024-10-30

PDB statisticsPDBj update infoContact PDBjnumon