Loading
PDBj
MenuPDBj@FacebookPDBj@TwitterPDBj@YouTubewwPDB FoundationwwPDB
RCSB PDBPDBeBMRBAdv. SearchSearch help

5CVM

USP46~ubiquitin BEA covalent complex

Experimental procedure
Experimental methodSINGLE WAVELENGTH
Source typeSYNCHROTRON
Source detailsALS BEAMLINE 5.0.2
Synchrotron siteALS
Beamline5.0.2
Temperature [K]100
Detector technologyCCD
Collection date2012-10-17
DetectorADSC QUANTUM 315
Wavelength(s)0.9794
Spacegroup nameC 2 2 21
Unit cell lengths90.613, 105.120, 134.656
Unit cell angles90.00, 90.00, 90.00
Refinement procedure
Resolution27.820 - 1.900
R-factor0.1767
Rwork0.176
R-free0.19720
Structure solution methodMOLECULAR REPLACEMENT
RMSD bond length0.010
RMSD bond angle1.030
Data reduction softwareDENZO
Data scaling softwareSCALEPACK
Phasing softwarePHASER
Refinement softwareBUSTER (2.11.5)
Data quality characteristics
 OverallInner shellOuter shell
Low resolution limit [Å]27.82050.0001.970
High resolution limit [Å]1.9004.0901.900
Rmerge0.0300.805
Number of reflections50336
Completeness [%]99.597.6
Redundancy5.95.9
Crystallization Conditions
crystal IDmethodpHtemperaturedetails
1VAPOR DIFFUSION, HANGING DROP2923.6 M sodium formate

227111

PDB entries from 2024-11-06

PDB statisticsPDBj update infoContact PDBjnumon